- safety category of the circuit (you need to know the architecture of the circuit, i.e. whether it is a single-channel circuit, a single-channel circuit with cycle testing or a dual-channel circuit)
- the MTTFD of the various devices used (this parameter indicates device reliability)
- diagnostic coverage (DC, this parameter indicates the system’s ability to self-detect any possible internal failures)
- common cause failure (CCF - applies only to category 2, 3 and 4 circuits and analyses all common cause failures that can compromise system redundancy).
Switches with positive opening action don’t have an elastic linkage between the moving contacts and the actuator to which the actuating force is applied. All positive-opening switches carry the positive-opening symbol on the cover. A switch with spring rod, for example, cannot have positive-opening contacts. If only one switch is used in a safety application, the switch must be actuated in positive mode.
For safety applications, the opening contact (normally closed) must be with “positive opening”: All switches with the symbol are provided with NC contacts with positive opening. In case of two or more switches, they should operate in opposite modes, for example:
- the first with an NC contact (normally closed contact), actuated by the guard in positive mode;
- The other with an NO contact (normally open contact), actuated by the guard in negative mode.
This is a common practice, though it does not exclude the possible use of two switches that are actuated in positive mode (see diversification).

A snap-action switch has a contact carrier that moves independently from the actuation speed (even if actuation is slow, the contacts snap apart rapidly, producing a distinct “click”).
These switches are suitable for applications that involve high currents and/or slow actuation movements (the electric arc is interrupted by the snap action of the contact carrier).

For the installation of switches with safety functions:
- only use switches with positive-opening contacts,
- connect the safety circuit to the normally closed contacts (11-22, 21-22, 31-32),
- actuate the switch at least up to the positive-opening travel indicated in the travel diagrams,
- install the switch so that the switch completes the positive-opening travel upon opening of the guard.
The differential travel is the difference (only for snap-action contact blocks) between the switching point on forward travel and the switching point on return travel. Essentially, the contact block does not snap at the same point. For example, for contact block B5, the forward operating travel distance is 2 mm, while on return travel it is 1 mm. The differential travel is therefore 1 mm.
N.B. for slow-action contact blocks, there is no differential travel.

First of all, it should be noted that the state of the contacts should be checked with the rope correctly tensioned and the reset knob in the armed position. The rope switch may be incorrectly adjusted or the rope may be slack or broken. We recommend checking the tensioning of the device rope following the instructions in the relevant section of the catalogue and operating manual (section 4.3 Rope installation) for rope safety switches.

First of all, it should be noted that the state of the contacts should be checked with the rope correctly tensioned and the reset knob in the armed position. The rope switch may be incorrectly adjusted or the rope may be slack or broken. We recommend checking the tensioning of the device rope following the instructions in the relevant section of the catalogue and operating manual (section 4.3 Rope installation) for rope safety switches.

The operating manual (and catalogue) contains examples of installation in paragraph 4.4 Installation examples. These include examples for switches with longitudinal and transversal heads, along with indication of the maximum spans and rope lengths for rope safety switches based on usage.
Paragraph 4.5 Rope tightening contains tables indicating how the maximum lengths recommended vary for different installations. These depend on the temperature fluctuations (temperature difference) it is expected that the switch will be exposed to in the work environment.

The BC series, on the other hand, does not perform any safety or communication function. It serves exclusively to make wiring quicker and better organised, distributing device signals to I/O modules or external safety relays.

Via input I3 it is possible to replace the coded actuator with a second actuator at any time (refer to paragraph 5.6 Actuator replacement in the operating manual).
OSSD (output signal switching device) outputs are solid-state commutation devices used in industrial safety circuits (photoelectric barriers, sensors and laser scanners).
They constantly monitor the signal, ensuring reliability, advanced diagnostics for short circuits and immediate blocking of the machine in the event of failure.
Redundancy: They typically operate in pairs (dual channel) for reciprocal monitoring of signal integrity.
Auto-test: They issue brief test impulses to detect short circuits to the supply voltage (+24Vdc) or to earth (0V).
Active safety: If a failure or interruption is detected (e.g. person crosses the barrier), the output changes immediately from ON (+24Vdc) to OFF (0V), stopping the machine.
Low voltage: Supplied with direct current (+24Vdc), they usually manage safety relays or controllers.
With manual reset, the module is activated on the rising edge of the reset signal. With monitored reset, activation is on the falling edge of the reset signal. In the case of monitored start, any sticking or breakage of the button in contact-closed state is detected. With monitored start, such a failure changes the start from manual to automatic.
In fact, CS AT modules manage single or dual-channel inputs, safety outputs with instantaneous contacts and safety outputs with contacts delayed upon de-energizing.
Essentially, they perform an “off delay” function. Opening of at least one of the input channels will trigger immediate deactivation of the instantaneous outputs and, after a fixed or settable delay, deactivation of the delayed contacts.
CS FS modules, on the other hand, are safety timer modules that enable timing of the safety output. The main difference between a CS AT module and a CS FS module is that the safety timers of the CS FS series are only equipped with delayed contacts (they do not have instantaneous contacts).
There are various types of CS FS timer modules:
- With CS FS 1 and 2, the safety function is set up so that from the moment the supply voltage is applied to the module, a time delay is applied, after which the outputs, with switch-on delay contacts, are activated.
- With CS FS 3, the safety function is set up so that from the moment the supply voltage is applied to the module, a time delay is applied, after which the contacts delayed on energization are deactivated.
- With CS FS 5, the safety function is set up so that on opening of at least one of the input channels, a time delay is applied, after which the outputs, with switch-off delay contacts, are deactivated.
No, that is not possible. The contacts on BN push-button panels are fitted directly onto the circuit board and therefore cannot be replaced by the customer.
No, that is not possible. The 4-position selector switch is only compatible with dedicated contacts mounted on a 3-slot mounting base (E2 1BAC1*). To avoid ordering errors, 4-position selector switches are not available as a separate device, but only as the E2 AC-DXBC**** assembly (selector switch + base + contacts).